TCR1000SDKRev.3.0.0  Page13
TCR1000_ApiClearEnhanced
TheTCR1000_ApiClearEnhancedfunctionforcesoffallenabledenhancedinterruptfeaturesonthe
TCR1000
timecodereadercard.
BOOLTCR1000_ApiClearEnhanced(void)
Parameters
Thisfunctionhasnoparameters.
ReturnValues
ReturnsTRUEifallenhancedfeaturesclearedsuccessfully.ReturnsFALSEifunabletoclearenhanced
features.
Remarks
UseofthisfunctiondefiesthemultithreadsafecapabilityofthisAPIandisnotrecommendedforuse
inanenvironmentwheremultipleapplicationswillusetheasynchronousnotifications.
TCR1000_ApiRequestRecalibration
TheTCR1000_ApiRequestRecalibrationfunctionforcestheTCR1000cardtorecalibratethe
automaticgaincontroltotheincomingtimecode’ssignallevel.
BOOLTCR1000_ApiRequestRecalibration(void)
Parameters
Thisfunctionhasnoparameters.
ReturnValues
ReturnsTRUEifrecalibrationstartedsuccessfully.
Remarks
OncetheTCR1000cardhasdetectedthetimecodeformatandcalibrated
itsgainleveltothetime
code’ssignallevelitwillexpectthatleveltoremainconstant.Ifthetimecodeformatchangesorthe
levelfluctuates,thecardmayceasetodecodetimecodeproperly.Inasituationwherealevelchange
isanticipated,suchasaswitchtoadifferenttimecodefeed,thisAPIinstructstheTCR1000to
recalibratethegain.
ThisfunctioncanbeusedtoswitchbetweenSMPTEandIRIGBtimecodes.